CertificatesGLP-3R Research Peptide · Batch RET15002
GLP-3R Research Peptide

GLP-3R Research Peptide

Endotoxin Cleared15mgPurity 99.71%Current lot RET15002
Shop product →
Certificate of Analysis · Current Shipping Lot

GLP-3R Research Peptide — 15mg

Purity (HPLC-UV)
99.71%
Spec ≥ 98.0%
Batch / Lot
RET15002
1 lot(s) on file
Test Date
May 16, 2026
Report issued
Endotoxin
Cleared
USP <85> LAL
Sensitivity
≤0.05 EU/mL

Sample Summary

Identifying details for the specific vial and lot submitted for third-party analysis.

FieldResult
ProductGLP-3R Research Peptide
Peptide (as tested)GLP-3R 15mg
Size / Strength15mg
Batch / LotRET15002
Accession #2605130365
Search CodeFitA2605130365
CAS #2381089-83-2
Test DateMay 16, 2026
AppearanceWhite Lyophilized Powder
IdentityGLP RT (LC-MS)
What this is: the chain-of-custody header for the tested unit. The accession number ties this certificate to the laboratory’s internal record so any result can be independently re-verified with Freedom Diagnostics.

Purity Analysis

Quantifies how much of the sample is the intended compound versus related impurities.

Purity (HPLC-UV)
99.71%
Area-under-curve at 214 nm
Identity (LC-MS)
GLP RT
Observed mass matches theoretical
Net Peptide Content
15.97 mg
Per labeled vial
What this measures: HPLC-UV separates the sample and measures the target peptide’s peak area against impurity peaks — reported as a purity percentage. LC-MS confirms identity by mass. Net peptide content reflects the actual mass of active peptide in the vial.

Endotoxin Analysis

Screens for bacterial endotoxin (lipopolysaccharide) using the LAL method per USP <85>.

Result
Cleared
Below detection threshold
Sensitivity
≤0.05 EU/mL
Assay limit of detection
Method
LAL · USP <85>
Run in duplicate
What this measures: the Limulus Amebocyte Lysate (LAL) assay detects bacterial endotoxin down to the stated sensitivity. “Cleared” means none was detected above the assay’s limit. Tested in duplicate.

Full Certificate (PDF)

The signed laboratory report exactly as issued by Freedom Diagnostics.

Your browser can’t display the embedded PDF. Open the certificate ↗

Test History

All batches tested for this product. Average and range are computed across every lot on file.

Average Purity
99.71%
Across all lots on file
Range
99.71% – 99.71%
Min – max observed
Lots On File
1
Batch-level certificates
Batch / LotSizePurityTest DateEndotoxin
RET1500215mg99.71%May 16, 2026ClearedView →
Research Use Only — Not for Human or Veterinary Consumption. All products are sold strictly as research-grade biochemical reference compounds for in-vitro laboratory and analytical research by qualified professionals. Certificates of Analysis attest to laboratory test results for a sampled batch only and do not constitute any representation of safety or suitability for human use. Lab partner: Freedom Diagnostics · Endotoxin USP <85>.